m |
|||
Line 31: | Line 31: | ||
| align="center" | Send key to panel | | align="center" | Send key to panel | ||
|} | |} | ||
+ | |||
+ | ==Reboot== | ||
+ | ==Zone Emulation== | ||
+ | ==Function Keys== | ||
=Device Configuration= | =Device Configuration= | ||
Line 102: | Line 106: | ||
==Prompted== | ==Prompted== | ||
− | If you send <b>!</b> followed by a carriage return you will be prompted | + | If you send <b>!</b> followed by a carriage return you will be prompted to configure each field. This prompt also includes a basic description of the setting as well as it's current value. |
− | <b>You may hit enter to keep the current value or | + | <b>You may hit enter to keep the current value or provide a new one.</b> |
Example: | Example: | ||
Line 130: | Line 134: | ||
==Programmatic== | ==Programmatic== | ||
− | You may retrieve all of the | + | You may retrieve all of the current device settings by sending <b>C</b> to the panel followed by a carriage return (\r). |
− | Retrieving | + | Retrieving settings: |
* Send: <b>C\r</b> | * Send: <b>C\r</b> | ||
* Response: <b>!CONFIG>ADDRESS=18&CONFIGBITS=ff00&LRR=N&EXP=NNNNN&REL=NNNN&MASK=ffffffff&DEDUPLICATE=N</b> | * Response: <b>!CONFIG>ADDRESS=18&CONFIGBITS=ff00&LRR=N&EXP=NNNNN&REL=NNNN&MASK=ffffffff&DEDUPLICATE=N</b> | ||
Line 148: | Line 152: | ||
==Keypad== | ==Keypad== | ||
− | Keypad messages have an optional header that can be enabled in the [[#CONFIGBITS|CONFIGBITS]]. This setting prefixes all keypad messages with <b>!KPM:</b>. | + | Keypad messages are by far the most common message type produced by the AlarmDecoder. These messages also have an optional header that can be enabled in the [[#CONFIGBITS|CONFIGBITS]]. This setting prefixes all keypad messages with <b>!KPM:</b>. |
{| align="center" class="wikitable" border="1" | {| align="center" class="wikitable" border="1" |
Revision as of 13:33, 17 December 2013
Contents |
Commands
Command | Description |
---|---|
= | Reboot the device. |
! | Configure the device via prompts. |
C | Sets or retrieves configuration parameters. |
L | Emulate virtual zone opens and closes. |
\x01\x01\x01 | Send Function Key #1 |
\x02\x02\x02 | Send Function Key #2 |
\x03\x03\x03 | Send Function Key #3 |
\x04\x04\x04 | Send Function Key #4 |
0123456789*# | Send key to panel |
Reboot
Zone Emulation
Function Keys
Device Configuration
The AlarmDecoder configuration can be viewed or modified in one of two ways: prompted or programmatically.
Name | Default Value | Valid Values (Regex) | Description |
---|---|---|---|
ADDRESS | 18 | [0-9]{2} | Keypad address assigned to the AlarmDecoder. |
CONFIGBITS | FF00 | [0-9a-f]{4} | Special settings for the device. See CONFIGBITS for more information. |
MASK | FFFFFFFF | [0-9a-f]{8} | Address mask used to filter for keypad alphanumeric messages. |
EXP | NNNNN | [YN]{5} | Emulation of zone expanders 1-5 |
REL | NNNNN | [YN]{4} | Emulation of relay expanders 1-4 |
LRR | N | [YN] | Emulation of Long Range Radio expander |
DEDUPLICATE | N | [YN] | If enabled, removes duplicate alphanumeric keypad messages. |
CONFIGBITS
CONFIGBITS is a setting that's used to enable special functionality on the AlarmDecoder. You can enable these by masking the correct bits.
Mask | Description |
---|---|
0x0001 | Enable reporting of AUI messages. |
0x0002 | Enable reporting of keypress events. |
0x0004 | Disable prompts for L and | commands. |
0x0008 | Enable the prefixing of panel messages with !KMP. |
0x0100 | Enable reporting of RFX messages. |
Prompted
If you send ! followed by a carriage return you will be prompted to configure each field. This prompt also includes a basic description of the setting as well as it's current value.
You may hit enter to keep the current value or provide a new one.
Example:
!>Ademco/DSC Mode A/D (A) :> !>Keypad Address (18) :> !WARNING. Do not enable a module if the physical module exists on the system. !Zone Expanders Y/N Max allowed: 02 !>expander module #01 ZN 09-16 (N) :> !>expander module #02 ZN 17-24 (N) :> !>expander module #03 ZN 25-32 (N) :> !>expander module #04 ZN 33-40 (N) :> !>expander module #05 ZN 41-48 (Y) :> !Relay Modules Y/N Max allowed: 04 !>relay module #01 (Y) :> !>relay module #02 (N) :> !>relay module #03 (N) :> !>relay module #04 (N) :> !>Emulate Long Range Radio Y/N: (Y) :> !>ZoneTracker track zone restore Y/N: (N) :> !>Address Filter Mask (ffffffff) :> !>Deduplicate (N) :> !>Config Bits (ff04) :>
Programmatic
You may retrieve all of the current device settings by sending C to the panel followed by a carriage return (\r).
Retrieving settings:
- Send: C\r
- Response: !CONFIG>ADDRESS=18&CONFIGBITS=ff00&LRR=N&EXP=NNNNN&REL=NNNN&MASK=ffffffff&DEDUPLICATE=N
It can also be used to set values:
- Send: CADDRESS=20\r
- Response: !>ADDRESS=20
The same command may be used to set multiple values:
- Send: CADDRESS=20&DEDUPLICATE=Y\r
- Response: !>ADDRESS=20&DEDUPLICATE=Y
Message Types
There are several types of messages produced by the AlarmDecoder. These include: Keypad, Relay Expander, Zone Expander, RFX, LRR, and AUI.
Keypad
Keypad messages are by far the most common message type produced by the AlarmDecoder. These messages also have an optional header that can be enabled in the CONFIGBITS. This setting prefixes all keypad messages with !KPM:.
[001000010000--------],010,[f70700060010808c08020000],"ARMED ***STAY** ZONE BYPASSED " | |||
Bit field | Numeric code | Raw data | Alphanumeric Keypad Message |
---|---|---|---|
[001000010000--------] | 010 | [f70700060010808c08020000] | "ARMED ***STAY** ZONE BYPASSED " |
Zone Expander
!EXP:07,01,01 | |||
Header | Zone Expander Address | Expander Channel | Data |
---|---|---|---|
!EXP | 07 | 01 | 01 |
Relay Expander
!REL:12,01,01 | |||
Header | Relay Expander Address | Expander Channel | Data |
---|---|---|---|
!REL | 12 | 01 | 01 |
RFX
!RFX:0180036,80 | |||
Header | Serial Number | Data | |
---|---|---|---|
!RFX | 0180036 | 80 |
LRR
!LRR:012,1,ARM_STAY | |||
Header | Event Data | Partition | Event Type |
---|---|---|---|
!LRR | 012 | 1 | ARM_STAY |
AUI
TODO
Keypress Events
TODO