There are several types of messages produced by the AlarmDecoder. These include: Keypad, Relay Expander, Zone Expander, RFX, LRR, and AUI.
Commands
Message Types
Keypad
Example Keypad Message
[001000010000--------],010,[f70700060010808c08020000],"ARMED ***STAY** ZONE BYPASSED "
|
|
Bit field
|
Numeric code
|
Raw data
|
Alphanumeric Keypad Message
|
[001000010000--------]
|
010
|
[f70700060010808c08020000]
|
"ARMED ***STAY** ZONE BYPASSED "
|
Zone Expander
Example !EXP Message
!EXP:07,01,01
|
|
Header
|
Zone Expander Address
|
Expander Channel
|
Data
|
!EXP
|
07
|
01
|
01
|
Relay Expander
Example !REL Message
!REL:12,01,01
|
|
Header
|
Relay Expander Address
|
Expander Channel
|
Data
|
!REL
|
12
|
01
|
01
|
RFX
Example !RFX Message
!RFX:0180036,80
|
|
Header
|
Serial Number
|
Data
|
!RFX
|
0180036
|
80
|
LRR
Example !LRR Message
!LRR:012,1,ARM_STAY
|
|
Header
|
Event Data
|
Partition
|
Event Type
|
!LRR
|
012
|
1
|
ARM_STAY
|
AUI
TODO