Protocol

Revision as of 11:59, 17 December 2013 by 204.10.16.29 (Talk)

There are several types of messages produced by the AlarmDecoder. These include: Keypad, Relay Expander, Zone Expander, RFX, LRR, and AUI.

Contents

Commands

Message Types

Keypad

Example Message
[001000010000--------],010,[f70700060010808c08020000],"ARMED ***STAY** ZONE BYPASSED "
 
Bit field Numeric code Raw data Alphanumeric Keypad Message
[001000010000--------] 010 [f70700060010808c08020000] "ARMED ***STAY** ZONE BYPASSED "

Zone Expander

Example Message
!EXP:07,01,01
 
Header Zone Expander Address Expander Channel Data
 !EXP 07 01 01

Relay Expander

Example Message
!REL:12,01,01
 
Header Zone Expander Address Expander Channel Data
 !REL 12 01 01

RFX

Example Message
!RFX:0180036,80
 
Header Serial Number Data
 !RFX 0180036 80

LRR

Example Message
!LRR:012,1,ARM_STAY
 
Header Event Data Partition Event Type
 !LRR 012 1 ARM_STAY

AUI

TODO